Virginia Building Code Requirements for Spray Foam Insulation
Choosing the right spray foam insulation for your Virginia pole barn can be challenging. With humid summers and cold winters, Virginia’s climate zones require careful consideration of R Values, moisture control, and code compliance. In this article, we break down the differences between closed cell and open cell spray foam, share updates from the 2021 Virginia Residential Code, and outline county-specific requirements. You’ll walk away with everything you need to know to insulate your pole barn garage, workshop, house, or storage building the right way.
Virginia Building Code Requirements for Spray Foam Insulation
Code Editions Used in Virginia
Most counties follow the 2021 Virginia Residential Code (VARC), based on the 2021 International Residential Code (IRC). Always confirm with your local building department. For example:
- Fredericksburg City and Spotsylvania County use VARC 2021 with local amendments.
- Albemarle County and Charlottesville may require newer code versions.
- Madison County and King George County generally follow VARC 2021.
Climate Zones and R Value Requirements
Virginia includes two climate zones:
- Zone 4: Fredericksburg, Spotsylvania, King George
- Zone 5: Charlottesville, Albemarle, Madison, Staunton
As per VARC Table N1102.1.2:
- Zone 4: Minimum ceiling insulation R 49
- Zone 5: Minimum ceiling insulation R 60
If insulating an unvented roof with spray foam, VARC Section R806.5 applies. It requires continuous coverage of foam over roof sheathing with minimum R Value compliance.
More on R Values and requirements is available from the US Department of Energy.
Closed Cell vs Open Cell Spray Foam: Technical Comparison
R Value and Performance
| Feature | Closed Cell | Open Cell |
|---|---|---|
| R Value per inch | R 6 to R 7 | R 3.7 to R 3.8 |
| Thickness for R 49 (Zone 4) | 7 to 8 inches | 13 to 14 inches |
| Vapor Barrier | Yes | No |
| Air Sealing | Excellent | Good |
| Adds Structural Strength | Yes | No |
Moisture Control
- Closed Cell: Impermeable and ideal for humid climates. Prevents condensation under metal roofing.
- Open Cell: Vapor permeable and requires an added interior vapor barrier. Not ideal for metal-roof pole barns in humid regions.
EPA spray foam safety and moisture guide: https://archive.epa.gov/epa/saferchoice/spray-polyurethane-foam-spf-insulation-and-how-use-it-more-safely.html

County Specific Requirements in Virginia
Fredericksburg and Spotsylvania
- Follow VARC 2021
- Closed cell is preferred under metal roofs
- Minimum R 30 required for unvented ceilings
- Open cell must have vapor barrier and reach R 49
Charlottesville and Albemarle
- Enforce Zone 5 R 60 ceiling insulation
- Closed cell foam preferred for unvented roof decks
- Open cell must have polyethylene vapor barrier
Madison and Staunton
- Require R 60 ceilings for conditioned spaces
- Closed cell preferred for cathedral or metal roofs
King George and Orange Counties
- Require R 30 minimum for closed cell under metal roofs
- Vapor barrier enforcement is strict
Installation and Inspection Tips
Before You Spray
- Confirm your jurisdiction’s building code version
- Hire a DPOR licensed contractor
- Provide energy compliance reports with R Value documentation
During Installation
- Use depth gauges to verify foam thickness
- Ensure continuous coverage under roof sheathing
- Apply ignition or thermal barriers as required
Thermal Barrier Requirements
Closed cell and open cell both require ½ inch gypsum board unless using approved fire-rated coatings in unconditioned areas.
Best Applications
Closed Cell Foam
- Pole barn roofs
- Walls exposed to outside conditions
- High humidity or metal-roof environments
Open Cell Foam
- Interior walls and partition spaces
- Budget-friendly but less moisture-resistant
Frequently Asked Questions
Is closed cell worth the extra cost?
Yes, especially in Virginia’s climate. It provides better insulation per inch, acts as a vapor barrier, and strengthens roof and wall assemblies.
Do I need a vapor barrier with spray foam?
Only with open cell foam. Closed cell already acts as one.
How can I verify my contractor is licensed?
Search the DPOR license lookup. Always confirm foam meets ICC AC377 standards.
Why Choose Spear Builders for Your Spray Foam Project
Spear Builders has served Central Virginia since 1987, offering complete custom builds and pole barn solutions across:
We handle permits, code compliance, material selection, and installation from start to finish.
Schedule a Free Insulation Consultation